SD8 Animated Detail Overlook

Hot-Rolled Column to Main Frame Rafter

This detail shows the connection of a hot rolled interior column to a Rigid Frame Rafter at an end-wall. The roof purlin also shown in the detail is just shown for orientation.

The clip that is pre-welded to the rafter should be placed on the outside of the column web. This clip is typically slotted to allow for rafter deflection at the column (not shown in the animation). A flat washer needs to be installed on the slotted side of the clip with the bolt.

  • What you will need:
    (2) 5/8” A325 Structural Bolts and Nuts (typically black)
  • (2)1/2” Washers

 

Tip:

1. The column should be placed prior to the roof rafter being raised

2. Based on anchor bolt accuracy it may make sense to install the rafter with the clip on the inside of the column. This will effectively move the column ¼” towards the peak of the roof. This should only be done if the corner columns are perfectly plumb.

Click here to view a PDF drawing of SD8

Your Quote is on it’s way!

You should receive your estimated quote by email shortly. Please keep in mind that this is just an estimate and does not include snow loads, wind loads, county specific code requirements, delivery or design specific engineering calculations related to the structural soundness of the building.

Text Messaging

Would you like a response via text message? Opting into SMS indicates you agree to receive SMS messages regarding your request from Great Western Buildings. Message and data rates may apply. Message frequency may vary. To end messaging from us, you may always reply with STOP. You may also reply with HELP for more information.